Insulation Displacement Connectors (IDC) - NDC 2018A

(NDC 2018A)
10
Package Qty: 200
Quantity:
 
Features
  • Easy connection by using pliers.
  • No need for wire stripping.
  • Simple structure for single connection.
Specifications
  • L1: 26mm / 1.02"
  • L2: 43.2mm / 1.7"
  • w: 7.8mm / 0.31"
  • h: 8.5mm / 0.33"
  • Rated Voltage: 300V
  • Material (Housing): Polycarbonate (Black)
  • Standards: VDE
  • RoHS: RoHS 10
  • Wire Size Range for Solid Wire (mm): -
  • Wire Size Range for Stranded Wire (mm²): 0.50-0.75
  • AWG: 20-18
  • Max. Wire Outside Diameter: 2.8mm / 0.11"
  • Rated Current: 6A (AWG 20), 8A (AWG 18)
  • Insulation Maximu Operating Temperature: 248°F / 120°C
  • Working Temperature Range: 32°F to 104°F / 0°C to 40°C
  • Material (Cover): Polycarbonate (Green Translucent)
  • Material (Connector Contact): Tin plated copper alloy